Controller for Smart Building

Controller für Office und größere Gebäude. SB2WEB24

Sammeln Sie mit dem Kauf dieses Artikels bis zu 52 Treuepunkte. Ihr Warenkorb hat insgesamt 52 points die umgewandelt werden können in einen Gutschein im Wert von 26,00 kr.


BACnet Controller for HVAC and lighting systems

• Ethernet port for BACnet/IP and Modbus/TPC communi- cation
• Modbus-RTU master RS485 port for connection of Carlo Gavazzi energy meters
• Functions for control of lighting, blinds, temperature, logic, scheduling, sequencing, alarms and data logging
• BTL certified • User-friendly PC-based configuration tool
• 12 to 28 VDC Power Supply

Mehr Infos

SB2WEB24

5 285,00 kr

  • SB2WEB24 ist für Büro und größere Gebäude

    BACnet Controller for HVAC and lighting systems

    DATAblad DK DATAblad Uk DATAblad DE

    Software og Firmware version.

    • Ethernet port for BACnet/IP and Modbus/TPC communi- cation
    • Modbus-RTU master RS485 port for connection of Carlo Gavazzi energy meters 
    • Functions for control of lighting, blinds, temperature, logic, scheduling, sequencing, alarms and data logging 
    • Functions and parameters can be monitored and con- trolled via BACnet/IP objects 
    • BACnet/IP objects are automatically created for all Dupline® and Energy Meter data points 
    • Manages up to 7 Dupline® Master Generators 
    • BTL certified • User-friendly PC-based configuration tool
    • Dimension: 2-DIN housing 
    • 12 to 28 VDC Power Supply

    DATASHEET pdf_icon.gif
    INSTALLATION MANUAL pdf_icon.gif
    INSTALLATION MANUAL pdf_icon.gif
    USER MANUAL pdf_icon.gif
    INSTALLATION MANUAL pdf_icon.gif
    CE CERTIFICATION pdf_icon.gif

    Product Description

    The SB2WEB24 programmable BACnet Controller is the brain and central unit in Carlo Gavazzi’s integrated concept for HVAC and lighting control in smart buildings. On one hand the SB2WEB24 can manage the complete lighting control system based on Dupline® sensors/actuators and DALI actuators, and on the other hand it can operate as Dupline® – BACnet/IP gateway thus allowing DDC controllers to use Dupline® I/O modules and sensors as decentralized I/O via BACnet objects. The SB2WEB is also able to operate as Modbus/ TCP slave. The SB2WEB provides functions for control of lighting, blinds, temperature, logic, scheduling, sequencing, alarms and data logging. The functions can be controlled, monitored and operational parameters changed via BACnet objects. The SB2WEB24 can manage data points from up to 7 Dupline® networks, each driven by a Dupline® Master Channel Generator (SH2MCG24) connected via the right side connector or via an external RS485 link. Only Dupline® modules supporting the Smart Dupline® protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication with CG energy meters. All electrical parameters from the energy meters are made available as BACnet objects. Via the PC-based configuration tool the user defines which modules are connected to the SB2WEB24 and the SH2MCG24s and the unique SIN-address for each Dupline® module is entered. Subsequently the configuration tool will automatically configure all connected Dupline® modules via the bus, and create the relevant BACnet objects.

    Mode of Operation

    The SB2WEB24 BACnet gateway needs to be configured to become operational. When the SB2WEB24 is connected to the TCP/IP network, the user can scan the system via the PC-based configuration tool to discover all Dupline® and DALI modules connected. It is also possible to enter the modules manually in offline mode. Each Dupline® module has a so-called SIN address (printed on the packaging and on the module) which must be entered during the configuration process to provide a unique identification of the item. Subsequently, the tool will automatically configure the connected Dupline® modules over the bus. Once all modules with data points have been defined, it is possible to define the functions that use them. Some of the functions are predefined (e.g. lighting, alarm, temperature) with inputs, outputs and operational parameters, while others are standard types, such as logic, timers, real-time, sequence, data logging etc. In order to ease testing and troubleshooting during commissioning, the configuration tool also provides the option to monitor live data from the SB2WEB24. All physical data points in the system are automatically made available as BACnet/IP objects, thus making it easy for external DDC controllers to use them as a remote I/O. In addition, BACnet objects are created that allow monitoring and control (trigger) of the functions, as well as changing operating parameters (e.g. lux set-point for constant light function).

    Smart House Bilding backnet

    • Adresszuweisung Automatisch: Der Controller erkennt das Modul anhand der SIN (Specific Identification Number, eindeutige Identifikationsnummer) Sx2WEB24
    • Höhe 90 mm
    • Breite 35 mm
    • Tiefe 44 mm + 14,5 mm
    • Gewicht 150 g
    • Forside IP40
    • Schraubklemme IP 20
    • Beskyttelsesgrad 2 (IEC 60664-1, par. 4.6.2)
    • Betriebstemperatur -20° til +50°C
    • Lagertemperatur -30° til +70°C
    • Luftfeuchtigkeit (nicht-kondensierend) 20 til 80% RH
    • Haus Abmessungen 2-DIN-modul
    • Datenblatt / Bedienungsanleitung Download Datenblatt / Handbuch - klicken Sie auf die Registerkarte Download
    • Montage DIN-skinne
    • Information BACnet kommunikation protokol
    • Information 2 Kommunikationsporte • Ethernet: 1 port, til internet/LAN-forbindelse MOD BUS 1 og 2 Tilslutning A1 (+) og A2 (-)
    • Information 3 Højre side Kompatibel med SH2MCG24, SH2WBU230x og SH2DUG24 enheder
    • Stromversorgung Forsyning: 15 til 24 VDC +/- 20%

    Bewertungen

    Rang 
    14.01.2017

    Forskel på SB2WEB24 og SH2WEB24

    De eneste forskel er SB2WEB24 har en BACnet kommunikation protokol i sig.

    BACnet bruges i større bygninger når flere systemer skal tale sammen. Det kunne f.eks være et dupline anlæg og et CTS anlæg

    Fordelen ved BACnet frem for Modbus, er at man ikke behøver en adresseliste, da man kan scanne netværket og se hvad der er tilgængelig på de andre systemer

    I boliger bruger man aldrig BACnet

    • 1 von 1 Kunden fanden diese Bewertung hilfreich.

    Eigenen Kommentar verfassen !

    Eigene Bewertung verfassen

    Controller für Office und größere Gebäude. SB2WEB24

    Controller für Office und größere Gebäude. SB2WEB24

    BACnet Controller for HVAC and lighting systems

    • Ethernet port for BACnet/IP and Modbus/TPC communi- cation
    • Modbus-RTU master RS485 port for connection of Carlo Gavazzi energy meters
    • Functions for control of lighting, blinds, temperature, logic, scheduling, sequencing, alarms and data logging
    • BTL certified • User-friendly PC-based configuration tool
    • 12 to 28 VDC Power Supply