Smart House Solution Danmark

Search on blog

Smart House UWP

Home

Home

Home

Home

Smoke Detector

Smoke Detector

By buying this product you can collect up to 16 loyalty points. Your cart will total 16 points that can be converted into a voucher of 8,00 kr.


• Smoke detector using Tyndall effect
• Detection of smouldering fires and flaming fires with smoke development
• Detection of areas up to 60 m2
• Transmission of alarms and Alive signals via Dupline®
• Operating voltage supplied by Dupline® bus
• Battery backup if the Dupline® connection is interrupted
• Acoustic alarm > 85 dB
• Constant monitoring of sensor sensitivity via Dupline®

More details

1 633,75 kr

  • • Smoke detector using Tyndall effect
    • Detection of smouldering fires and flaming fires with smoke development
    • Without radioactive sources
    • Detection of areas up to 60 m2
    • Transmission of alarms and Alive signals via Dupline®
    • Operating voltage supplied by Dupline® bus
    • Optional use of the smoke detector as alarm device for other detections such as gas, water and burglary via Dupline®
    • Battery backup if the Dupline® connection is interrupted
    • Acoustic alarm > 85 dB
    • Constant monitoring of sensor sensitivity via Dupline®
    • For ceiling mounting

    Product Description

    Ordering Key Decentral Smoke Detector No battery back-up Smart Dupline® Type Selection Battery back-up Supply by Dupline® YES BSG-SMO-U NO BSG-SMOA-U Smoke Detector Type BSG-SMOx-U BSG-SMOx-U is a detector for home/building applications which transmits the alarm event to the smarthouse controller. It is part of the smart-house concept and it can be used in all the functions where alarm signals are needed.

    Mode of Operation

    BSG-SMOx-U connected to the SH2WEB24 Coding/Addressing If the device module is connected to the SH2WEB24 controller, no addressing is needed since the module is provided with a specific identification number (SIN): the user has only to insert the SIN in the SH tool when creating the system configuration. Used channels: 1 input channel, 4 output channels. BSG-SMOx-U connected to BH8-CTRLX-230 Coding/Addressing If the input module is connected to the BH8-CTRLX- 230 controller, the user has to program the channels using the BGP-COD-BAT: this module has: - 4 output channels (I/O 1-4) - 1 input channel (I/O 5) CH1 is pre-programmed on N1, CH5 on N2. The alarm signal on CH1 can be programmed to be active when the alarm is ON or when the alarm is OFF. Fail/safe bit = 0 Signal active when the alarm is ON. Fail/safe bit = 1 Signal active when the alarm is not active.

    Mode of Operation Mounting To achieve minimum protection, one BSG-SMOx-U should be installed in front of each sleeping area or each floor. Higher protection will be achieved if one smoke detector is present in every room (except for the kitchen and the bath - here, false alarms may occur due to steam development). When using the BSGSMOX- u, the following issues must be observed: •Rooms may have a floor area of up to 60 m2 and a height of up to 6 m •Hallways and narrow corridors may have a width of up to 3 m (10 ft) and a length of up to 15 m (50 ft) •The mounting location must be as close as possible to the centre of the room •A minimum distance of 0.5 m (1.5 ft) must be maintained from walls and furniture The BSG-SMO-U must NOT be mounted in the following locations: •Near ventilation ducts or strong draughts •Directly in the apex of pitched roofs (a minimum distance of 30 cm (1 ft) from the apex must be maintained) • In rooms which are usually very steam-, dust- or smoke-filled (for example in workshops, bathrooms and laundry rooms) Connection of multiple smoke alarms It is possible to interconnect several smoke alarms so that the alarm signalfrom one alarm is transmitted to all other connected alarms. The smoke alarms are connected in parallel using a 2- wire cable. Note: Make sure that the total power consumption does not exceed the Dupline® controller’s output when interconnecting the smoke alarms. Use a back-up battery to avoid voltage drop in the Dupline® bus when using interconnection.

    • For Controller UWP 3.0 - SH2WEB24 - SB2WEB24 - SA2WEB24
    • Also compatible with ..: BH8-CTRLZ - BH8-CTRLX - G3800xx01x - or Dupline-Generator SH2DUG24
    • Address assignment Auto through "SIN" (Specific Identification Number) or via BGP-COD-BAT
    • Adressedeling. If it used with the BH8-CTRLX-230, the channels have to be programmed by the BGP-COD-BAT
    • Weight 160g
    • Protection IP 43
    • Operating temperature 0° til +50°C
    • Storage temperature -5° til +85°C
    • Humidity (non-condensing) 20 til 80% RH
    • Mounting ceiling
    • DIM.: Ø 100 x 54 mm
    • Color white
    • Information For installation in ceiling
    • Information 3 Gennemsnitl. levetid, batteri 2 år
    • Power supply Dupline Bussen Eller 9V

    Reviews

    Write a review

    Smoke Detector

    Smoke Detector

    • Smoke detector using Tyndall effect
    • Detection of smouldering fires and flaming fires with smoke development
    • Detection of areas up to 60 m2
    • Transmission of alarms and Alive signals via Dupline®
    • Operating voltage supplied by Dupline® bus
    • Battery backup if the Dupline® connection is interrupted
    • Acoustic alarm > 85 dB
    • Constant monitoring of sensor sensitivity via Dupline®

    Write a review

    19 other products in the same category: