By buying this product you can collect up to 7 loyalty points. Your cart will total 7 points that can be converted into a voucher of 3,50 kr.


• Passive infrared detector (PIR)
• For indoor applications
• Detects movement and presence
• Smart-house output
• Operating distance: 12 m
• Operating angle: 90°
• LED indication
• Supplied by bus

More details

BSD-PIR90-U

712,50 kr

  • • Passive infrared detector (PIR)
    • For indoor applications
    • Detects movement and presence
    • Smart-house output
    • Operating distance: 12 m
    • Operating angle: 90°
    • LED indication
    • Supplied by bus

    Product Description

    The BSD-PIR90-U is a 90° PIR sensor to detect presence and/or movement in indoor installations. It is part of the smart-house concept and can be used to control lights, rollerblinds, air-conditioning, intruder alarms and all the other functions supported by the smart-house system, in an automatic way depending on people-presence. This sensor is completely programmable via the SH tool.

    Mode of Operation

    This PIR sensor responds to any fluctuation in infrared heat radiation, so any object or human presence changes the thermal image detected by the sensor when entering its field of vision. The sensor is equipped with a segmented lens that divides the field of vision into active and passive zones (zones not visible to the sensor, see figures “Horizontal and Vertical sensitive area”). When a heat source crosses these zones, the sensor detects the change in infrared radiation and presence and/or movement are recognised. How sensitive and fast the sensor has to be to detect presence and/or movement can be programmed by means of four parameters, by means of the SH tool if the sensor is controlled by a master unit SH2WEB24 or by using the programmer BGP-COD-BAT if the sensor is connected to a BH8-CTRLX- 230. The four parameters are: mode of detecting the crossing of active zones, sensitivity, the number of pulses and the time window in which these pulses have to be detected. These four parameters have to be set for both presence and movement recognition. Movement is used by the system in the intruder alarm function and to switch the light on, while presence is used in the light function to reload the energy-save timer (i.e. each time presence is detected, the energy-save timer starts counting from the beginning). 1) Mode of detection A: one border between the active and the passive zone has to be crossed to give a pulse signal. This option has to be selected for presence detection and movement and turns the light on as soon as a person moves from an active to a passive area or vice versa (very quick response). B: two borders have to be crossed to give a pulse signal. The person has to move from an active area to another active area, passing through a passive one or vice versa. This option is recommended for sensors used in the intruder alarm function, in order to avoid false alarms. 2) Sensitivity A number can be set from 3 to 100: the smaller this value is, the longer the detection distance, but the higher the sensitivity to heating sources. In the figures “Horizontal and Vertical sensitive area”, three examples of different sensitivity can be seen. 3) Number of pulses The number of pulses is calculated according to mode A or B before sending a people detection message to the controller. This can be set from 1 to 8. 4) Time window This is the time interval within which the predefined number of pulses is detected. It can be set from 1 to 10 seconds. In the table below is an example of settings which, of course, might depend on environmental conditions, application and type of installation.

    Mounting

    The PIR detector is designed for wall mounting. As the BSD-PIR90-U is a passive device, several detectors can be placed in the same room without interfering with each other. The module should not be installed as follows: a) In places exposed either to sunlight or to motor vehicle headlights pointing directly at the sensor. b) In places exposed to direct air flow from a heater or air conditioner. c) In places where rapid temperature changes occur. d) In places exposed to severe vibration. e) Close to glass or other objects which might reflect the infrared radiation. Note: If the sensor is to detect presence, please be careful to mount it so that the area where presence has to be detected is completely covered by the sensitive area of the sensor. See figures “Horizontal and Vertical sensitive area”.

    • For Controller UWP 3.0 - SH2WEB24 - SB2WEB24 - SA2WEB24
    • Also compatible with ..: BH8-CTRLZ - BH8-CTRLX - G3800xx01x - or Dupline-Generator SH2DUG24
    • Address assignment Auto through "SIN" (Specific Identification Number) or via BGP-COD-BAT
    • Adressedeling. If it used with the BH8-CTRLX-230, the channels have to be programmed by the BGP-COD-BAT
    • Height 104 mm
    • Width 52 mm
    • Depth 62 mm
    • Weight 150 g
    • Protection Ip 40
    • Beskyttelsesgrad 3 (IEC 60664)
    • Operating temperature 0° til +50°C
    • Storage temperature -20° til +70°C
    • Humidity (non-condensing) 20 til 80% RH
    • DIM.: 104 x 52 x 62 mm
    • Color Hvid
    • Information Indoor
    • Power supply Supplied by Dupline®bussen

    Reviews

    Write a review

    Indoor PIR Sensor

    Indoor PIR Sensor

    • Passive infrared detector (PIR)
    • For indoor applications
    • Detects movement and presence
    • Smart-house output
    • Operating distance: 12 m
    • Operating angle: 90°
    • LED indication
    • Supplied by bus

    Write a review

    6 other products in the same category: