Floor sensor for  SHA4XTEMDIS og SHE5XTEMDIS

More details

BSO-TEMDIG

323,75 kr

  • Floor sensor for  SHA4XTEMDIS og SHE5XTEMDIS

    The floor's surface temperature

    The surface temperature should be 3 to 5 ° C higher than room temperature. The optimum temperature depends on the surface material, since different materials have different thermal conductivity. In the table you can see within which temperatures, the various materials operate most energy efficient:

     

     

    Material Temperature
    Stone, marble, concrete, clinker  27 minus thirty º C 
    Linoleum, PVC  25 -29 º C
    Wood, Cork  23 -28 º C
    Rugs  21 -28 º C

     

     For every degree the temperature is lowered, achieved a saving of 5% of energy consumption.


    Good advice

    • Ensure adequate insulation under floor heat 

        

    • The water in an underfloor heating installation is not as hot as in the radiators. That is why we need more water is circulated around the underfloor circuitrunning in order to keep the same ambient temperature. Why choose an A-mark circulation pump that has a low energy consumption 

        

    • All underfloor heating circuits should be guided by their own PIR, there must be 1.5 metres above the floor in a central location in the room without direct sunlight, pull or heat from other heating 

    • If you have tiled floors with waterborne underfloor heating, it does not pay to lower the temperature at night. This is because the floor heat is cast down into the floor and therefore react slowly on regulation. If you have hardwood floors, where varmerørerne is located just below the floorboards, on the other hand, it may well pay to lower the temperature at night. However, only with two degrees

       

    • Remember to turn off the floor heat in 4 to 5 hottest months of the year. Since airing more out in the summer, a powered-up underfloor installations lose much heat, even though the need for heating is less than in winter 

        

    • If you've got underfloor heating and elbaseret are away in less than a week in the winter season, it might not pay off to turn off the heat. Instead, lower the temperature by 5 to 6 ºc. If you are away for more than a week, it may well pay off to turn off the heat. Please be aware of the risk of moisture damage and frost damage to water pipes and urinals 

        

    • If you have water underfloor heating, you should never turn off completely in the winter. Even if you are away. This is because the underfloor heating pipes in such a case, frost blowing up.If you are away for a week or more, so style underfloor heating thermostat at 10 º C 

         

    • If you want to know how much energy you're using in floor heating, there is only one thing to do: read off a week's electricity demand on the electric meter. Turn off the heat, and read off the floor then consumption after a week. When you drag the two figures from each other, you will be given the floor heating electricity and can easily figure out what it costs per year

     

     

     

    Integrated Sensor 1 temperature sensor
    Range 0-50 ° c (32-122 ° f)
    Precision ± 1 ° c
    Floor sensor
    Temperature range 0-50 ° c (32-122 ° f)
    Cable length 4 m
    Cable consists of 4 wires:
    Brown Connect to "+" on Temperature
    controller
    White Connect two "c" on Temperature
    controller
    Yellow Connect two "d" on Temperature
    controller
    Green Connect two "T" on Temperature
    controller
    "See wiring diagram"
    The sensor is an electrical sensor and works only together with the
    Temperature Controller unit.

    • Weight 100g
    • Protection IP20
    • Beskyttelsesgrad 3 (IEC 60664)
    • Operating temperature 0° til +50°C
    • Storage temperature -20° til +70°C
    • Humidity (non-condensing) 20 til 80% RH
    • DIM.: Diameter 5.4 mm